- Overview
- Inquiry
- Related Products
- 1. Application
- 2. Composition and Features
- 3. Specifications
The MF15A gas masks is a protect equipment, with double-filtered respiration for the person. The masks can provide effective protection to the wearer’s face、eyes and respiratory tract. Prevent the harm of toxic、biological and radiation dust. It is designed for use in industry、agriculture、medicine and scientific research and civil defense etc.
MF15A gas masks components are the mask, the cartridge (double). The mask components are natural rubber mask (by injection molding, surface grinding)、lenses, breathing intercom and harness.
The hood sealing frame of the facepiece is designed according to the adults’ head shape, and use the opposite direction fold style、easy airtight. It is wearing comfortable, and applicable to more than 95% of adult citizens to wear.
The cartridge loads the excellent active carbon to be the catalyst, so it can be against a different kind of toxic. Its lifetime is long, resistance is small, and it is also light.
MF15A gas mask is produced according to GB2890-2009《GAS MASK USING TECHNICAL CANDITION》
3.1 Gas life: Depending on the selected canister.
3.2 Exhalation resistance: not more than 100pa (at 30 L/min)
3.3 Visual field:
Total visual field: not less than 75%.
Binocular visual field: not less than 60%.
Below the visual field: not less than 40 degrees.
3.4 Leak coefficient: not more than 0.005%.
3.5 Storage life: 5 years.
4. Use and safeguard
4.1 When wear mask, from the lower jaw to upward then properly adjust string. After wearing a mask,
Block up canister air entry by palm, then breath exert yourself, the facepiece tight stick with face,
No leak, indicate areas to work.
4.2 After using, clean all parts of sweat and dirties, especially lens, expiration valve, inspiration valve should be clean. If necessary, the mask surface may be washed with clear water, the canister should be clean also.
4.3 After using in virus environment of infected character, mask surface, and canister can be cleaned and disinfected with 1% peracetic acid disinfection. If necessary face piece can be soaked
in 1% peracetic acid disinfection. But the canister can't be soaked, prevent entering the water from losing efficacy. After the mask disinfecting with disinfected liquid should clean with clear water,
dry and stand-by.
5. Maintenance
5.1 Read the booklet detailed before using.
5.2 Gas mask which used in poison and evil environment. The person who didn’t pass special
training can't disassembly at will, reduce the part, and repair the product.
5.3 The product can't be used in the environment over 65℃, and it shouldn't be stored under high temperature.
5.4 The canister can decrease its adsorption capacity for toxic gases after it has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
5.5 The gas mask should be stored in a cool dry place. The facepiece must not contact the organic solvent.